← The Dosing Bench29.429.4 tonne/month
Phosphate removal (FeCl₃)
Ferric chloride to precipitate phosphorus to a target.
Ferric chloride 40%
- Fe required
- 13.5 mg/L
- Active FeCl₃
- 39.2 mg/L
- As product
- 97.9 mg/L
- Per day
- 978.75 kg
- Alkalinity consumed
- 36.3 mg/L
Method
D_Fe = r × ΔP × 1.80 ; FeCl₃ = D_Fe × 2.90 ; product = ÷ (S/100)
Reference: Metcalf & Eddy, Wastewater Engineering (chemical P removal).
Actual Fe:P depends on target residual P and matrix (1.5–3 in practice) — confirm by jar/plant trial. Ferric addition consumes alkalinity and can depress pH — check the alkalinity tool.
Estimated use: about 29.362 tonne/month of ChimiArt Ferric Chloride 40% for P-removal (ΔP 5 mg/L, Fe:P 1.5, flow 10000 m³/day).
Want to confirm this on your actual water? We can run a free jar test or send the grade's spec sheet.